set alarm

ecio_1xrtt

Alarms are triggered when the average Ec/Io 1xRTT signal strength on a CDMA device falls below a specified threshold for a specified amount of time. Optionally, a subsequent alarm is triggered when signal strength returns to the optimal state above the threshold.

ecio_1xevdo

Alarms are triggered when the average Ec/Io 1xEVDO signal strength on a CDMA device falls below a specified threshold for a specified amount of time. Optionally, a subsequent alarm is triggered when signal strength returns to the optimal state above the threshold.

mobile_temp

Alarms are triggered when the mobile temperature goes above a specified threshold. Optionally, a subsequent alarm is triggered when signal strength returns to a temperature below the threshold.

1xevdo_unavail

Alarms are triggered when 1xEVDO service is unavailable for a specified amount of time. Optionally, a subsequent alarm is triggered when service becomes available again.

mobile_unavail

Alarms are triggered when mobile service is unavailable (not registered on the home network) for a specified amount of time. Optionally, a subsequent alarm is triggered when service becomes available again.

config_change

Alarms are triggered when mobile configuration is changed.

priority={normalhigh}

The priority of the triggered email.

normal

The email is sent with normal priority.

high

The email is sent with high priority.

The default is “normal.”

subject=string

If “type=email,” this option specifies the text to be included in the “subject” field of an alarm-triggered email. If “type=snmptrap,” this option specifies the text to be included in the “Serial Alarm Subject” field of an alarm- triggered SNMP trap.

to=string

The text to be included in the “to” field of an alarm-triggered email.