Digi 90000566_H Mtwaitcount=count, Mdhrxkeepalive=time, Mdhtxkeepalive=time, Mdhwaitcount=count

Models: 90000566_H

1 278
Download 278 pages 26.72 Kb
Page 145
Image 145

set mgmtnetwork

mtwaitcount=count

Used to specify the wait count when the connection method is “mt,” where count is how many timeouts occur before the Digi device assumes the connection to the Connectware Manager server is lost and drops the connection.

mdhrxkeepalive=time

Used to specify the transmit keep alive time when the connection method is “mdh,” where time is the number of seconds to wait between sending keep-alive messages.

mdhtxkeepalive=time

Used to specify the receive keep alive time when the connection method is “mdh,” where time is the number of seconds to wait for a keep-alive message from the Connectware Manager server before assuming the connection is lost.

 

mdhwaitcount=count

 

Used to specify the wait count when the connection method is “mdh,”

 

where count is how many timeouts occur before the Digi device assumes

 

the connection to the Connectware Manager server is lost and drops the

 

connection.

Examples

Set instance 1 for proxy connection

 

#> set mgmtnetwork connectiontype=modemppp connectionmethod=proxy

 

proxyaddress=”What goes here?” proxyport=40002 proxylogin=”johnsmith”

 

proxypassword=”testpass” proxypersistentconnection=off

 

Set instance 2 for mdh connection

 

#> set mgmtnetwork connectiontype=ethernet connectionmethod=mdh

 

mdhrxkeepalive=100 mdhtxkeepalive=110 mdkwaitcount=15

 

Display current Connectware Device Protocol network settings

 

#> set mgmtnetwork

See also

"revert" on page 61.

 

"show" on page 249.

 

• For more information on Connectware Manager, see the Connectware

 

Manager Operator’s Guide, and the Connectware Manager online help.

Chapter 2 Command Descriptions

145

Page 145
Image 145
Digi 90000566_H manual Mtwaitcount=count, Mdhrxkeepalive=time, Mdhtxkeepalive=time, Mdhwaitcount=count