set term

set term

 

Devices

This command is supported in all Digi Connect products except

supported

ConnectPort Display.

Purpose

Allows for connecting a terminal to a device’s serial port and accessing the

 

command line of the device.

 

In the cases where the default access to the terminal and the command

 

line is “on,” this command is important if users want to use the serial port

 

for purposes other than having a command line. That is, they must change

 

the state of the serial port access from “on” to “off” in order to use the serial

 

port for another purpose.

Required

For Digi Connect products with two or more users, permissions must be set

permissions

to “set permissions s-term=read” to display terminal settings, and

 

“set permissions s-term=rw” to display and change terminal settings.

Syntax

Configure terminal settings

 

set term [state={onoff}]

 

Display current terminal settings

 

set term

Options

state={onoff}

 

Specifies whether terminal access is enabled for the serial port. The

 

default is “on” for Digi Connect WAN and Digi Connect RG devices.

Examples

#> set term

Serial Terminal Configuration :

port# state

1on

2on

See also

"revert" on page 61.

 

"show" on page 249.

Chapter 2 Command Descriptions

215

Page 215
Image 215
Digi 90000566_H manual Set term, Command line of the device, Port for another purpose, Configure terminal settings