Digi 90000566_H manual Register Definitions, Register Function Range Units Default

Models: 90000566_H

1 278
Download 278 pages 26.72 Kb
Page 267
Image 267

S-Register Definitions

S-Register Definitions

Following is a description of the S-registers that can be set.

Register

 

Function

Range

Units

Default

S0

Rings to Auto-Answer. Sets the number of rings required

0-255

Rings

0

before the Digi device automatically answers a call.

 

Setting this register to Zero disables auto-answer mode.

 

 

 

 

Ring Counter. Specifies the current number of rings. S1

 

 

 

S1

is incremented each time the modem detects a ring

0-255

Rings

0

signal on the telephone line. S1 is cleared when the

 

 

 

 

 

existing connection is established or dropped.

 

 

 

 

Escape Character. S2 holds the value of the ASCII

 

 

 

S2

character used as the escape character. The default

0-255

ASCII

43

value corresponds to an ASCII '+'. A value over 127

 

disables the escape process. That is, no escape

 

 

 

 

character will be recognized.

 

 

 

S3

Carriage Return Character. Sets the value of the

0-127

ASCII

13

carriage return character used when displaying

 

commands or results.

 

 

 

 

Line Feed Character. Sets the character recognized as

 

 

 

S4

a line feed when displaying commands or results. If

0-127

ASCII

10

verbose result codes are used, the Line Feed control

 

character is output after the Carriage Return control

 

 

 

 

character.

 

 

 

S5

Backspace Character. Sets the character recognized as

0-32

ASCII

8

a backspace, used to erase the last character typed on

 

the command line.

 

 

 

 

Escape Prompt Delay. The amount of time required

 

0.02

 

 

before and after an escape sequence (+++) is entered in

 

50

S12

0-255

second, 20

order for the modem to transition from data mode to

1 second

 

 

ms

 

command mode.

 

 

 

 

 

 

 

General Options Status. Indicates the status of

 

 

 

 

command options.

 

 

 

 

• Default: 138 (8Ah) (10001010b)

 

 

 

 

Bit 0: Ignored.

 

 

 

 

• Bit 1: Command echo (En):

 

 

 

 

 

0 = Disabled (E0).

 

 

 

 

 

1 = Enabled (E1). (Default.)

 

 

 

 

• Bits 2 and 4: Quiet mode (Qn):

 

 

 

S14

 

0 = Display result codes (Q0). (Default.)

 

 

138 (8Ah)

 

 

1 = Do not display result codes (Q1).

 

 

 

 

 

2 = Disables “CONNECT” result codes (Q2).

 

 

 

 

 

3 = Disables “CONNECT” result codes on incoming

 

 

 

 

 

connections (Q3).

 

 

 

 

• Bit 3: Result codes (Vn):

 

 

 

 

 

0 = Display numeric result codes (V0).

 

 

 

 

 

1 = Display verbose result codes (V1). (Default.)

 

 

 

 

Bits 5-7: Ignored.

 

 

 

Chapter 3 Modem Emulation Commands

267

Page 267
Image 267
Digi 90000566_H manual Register Definitions, Register Function Range Units Default