set udpserial

Options

Options for setting general UDP serial forwarding characteristics

 

port=range

 

Used to specify the serial port. Optional on a single-port device.

 

state={onoff}

 

Used to enable or disable sending data from the serial port to remote

 

network destinations. The default is “off.”

 

sendcount=bytes

 

The number of bytes received from the serial port that will cause the data

 

to be sent on to the network destinations. This trigger cannot be disabled.

 

The default is 1024 bytes.

 

sendtime={0time}

 

The amount of idle time, in milliseconds, allowed before sending data to

 

the network. If no data is received on the serial port for the time specified

 

by this option, any buffered data will be sent on to the network

 

destinations. A value of 0 (zero) disables this trigger.

endpattern=string

If this string is set, any pattern match of data received from the serial port will cause the data to be sent on to the network destinations. The maximum length of this string is 16 characters, including escape sequences for special characters. For more details on the escape sequences, see "Entering Special Characters in String Values" on page

13.The maximum parsed length of this string is 4 characters. That is, this string must reduce down to a 4-character string when the escape sequences are processed.

strippattern={onoff}

Determines how the data specified by the “endpattern” option is handled.

on

The endpattern that is found is stripped from the stream before any data is to be sent on to the network destinations.

off

The endpattern is not stripped from the stream before data is sent on to network destinations.

The default is “off.”