Image 77

set alarm

mode=ecio_1xevdo

Sets the alarm to 1xEV-DO Ec/Io signal-strength mode for a CDMA radio.

signal_strength_threshold=threshold

The threshold average signal strength., This is measured in dBm for rssi_gsm, rssi_1xrtt, and rssi_1xevdo (typically -120 dBm to -40 dBm) and dB for ecio_1xrtt and ecio_1xevdo (typically -24 dB to -2 dB).

Note that “0 dB” reported by a “display mobile” command when there is no signal strength should properly be interpreted as the minimum value, which is -120 dBm or -24 dB.

time=time

The time in minutes that the average signal strength stays below the threshold specified on the “signal_strength_threshold” option.

optimal_alarms_enabled={yesno}

If optimal alarms are enabled, an optimal alarm will also be sent when the signal strength returns to a value that is above the specified threshold. Default is no.

Cellular data traffic-based alarm options

These options for setting alarms based on cellular data traffic are supported in Digi Cellular Family products only.

mode=cell_data

Sets the alarm to cellular-data mode.

cell_data=byte count threshold

The number of bytes of cellular data to be counted before triggering an alarm.

cell_data_type={receivetransmittotal} The type of cellular data to be counted.

receive

Data received by the Digi Cellular device.

transmit

Data transmitted by the Digi Cellular device.

total

The total data received and transmitted the Digi Cellular device.

time=max time

The time, in minutes, during which bytes of cellular data are counted.

Chapter 2 Command Descriptions