set alarm

Options

General alarm options

 

state= {onoff}

 

Enables or disables all alarms.

 

on

 

Enables all alarms.

 

off

 

Disables all alarms. To avoid false errors, it is recommended that you

 

configure alarms while alarms are disabled, and enable alarms after

 

they are fully configured.

 

The default is “off.”

 

mailserverip=ipaddress

 

Used to configure IP address of the mail server to which alarm-triggered

 

emails are sent.

 

from=string

 

The text to be included in the “from” field of an alarm-triggered email.

 

cwm={onoff}

 

Enables or disables sending of alarm notifications to the Connectware

 

Manager server.

 

on

 

Send all alarm notifications to the Connectware Manager server. Turn

 

this option on if your Digi Connect device is managed by Connectware

 

Manager. Enabling this option is useful because it allows all alarms to

 

be monitored from one location, the Connectware Manager. Enabling

 

this option also allows Digi Connect devices to send alarms to clients

 

that would otherwise be unreachable from the Digi Connect device,

 

either because the Digi Connect device is behind a firewall or not on

 

the same network as the alarm destination.

 

off

 

Disables sending of alarm notifications to the Connectware Manager

 

server. Leave this option off if you do not manage your devices with

 

Connectware Manager or if you wish to have alarms sent from the

 

device, for example, because an SNMP trap destination is local to the

 

device, not the Connectware Manager server.

 

For more information on Connectware Manager, see the Connectware

 

Manager Operator’s Guide, and the Connectware Manager online help.

72

Chapter 2 Command Descriptions

Page 72
Image 72
Digi 90000566_H manual State= onoff, Mailserverip=ipaddress, From=string, Cwm=onoff