set bsc

set bsc

 

Devices

This command supported in Digi Connect WAN Sync only.

supported

 

Purpose

Configures the binary synchronous feature (also known as bisync or BSC)

 

that provides bisync to IP protocol configuration. This feature allows you to

 

attach a bisync terminal to the Digi device server’s serial port. The Digi

 

device server emulates the host by polling the terminal. The bisync data is

 

forwarded to the host over the TCP/IP network.

 

The Digi device can be configured in either client or server mode for bisync

 

communications.

 

Configuring the bisync feature involves:

 

• Enabling/disabling bisync communications and configuring serial

 

settings.

 

• Configuring polling settings.

 

• Configuring the network service settings for bisync communications.

 

Setting any of the bisync options will apply those options immediately, with

 

the current network connection. If the Digi device server is up and running,

 

has a network connection to the host, and you change the polling address,

 

the Digi unit will apply that to the next poll command it sends. However, if

 

you change anything on the network options, the current network

 

connection will be terminated, and a new connection will be established

 

using the new configuration.

Required

For Digi Connect products with two or more users, to use this command,

permissions

permissions must be set to one of the following:

 

• For a user to display bisync settings: “set permissions s-bsc=read”

 

• For a user to display and set bisync settings: “set permissions

 

s-bsc=rw”

 

See "set permissions" on page 157 for details on setting user permissions

 

for commands.