set surelink

Set TCP connection link test parameters:

set surelink [ipaddr1={ipv4 addressfqdn}] [ipaddr2={ipv4 addressfqdn}] [ipport=1-65535]

 

Display current SureLink settings

 

set surelink

Options

Options for Hardware reset thresholds

 

module_reset_connect_failures={1-2550=off}

The number of failed connection attempts that occur before the cellular modem module is reset. This value can be a number between 1 and 255, or 0, which turns off the cellular modem module-reset feature. The default is 3.

system_reset_connect_failures={1-2550=off}

The number of failed connection attempts that occur before the Digi Cellular Family device is reset. This value can be a number between 1 and 255, or 0, which turns off the system-reset feature. The default is 0, or off.

Options for Link Integrity Monitoring Tests

General link test options:

state={onoff}

Enables or disables link integrity monitoring tests. If “on,” the other Link Integrity Monitoring settings may be configured and are used to verify the functional integrity of the mobile connection. The default is “off.”

Chapter 2 Command Descriptions

203

Page 203
Image 203
Digi 90000566_H manual Moduleresetconnectfailures=1-2550=off, Systemresetconnectfailures=1-2550=off