8.0 GENERAL INFORMATION

 

N132K

N160K

 

N200H

 

N250H

N300H

General

 

 

 

 

 

 

 

Sound pressure level dB(A) *

75

75

 

75

 

80

80

Maximum ambient temperature ° C (° F)

46 (115)

46 (115)

 

46 (115)

 

46 (115)

46 (115)

Minimum ambient temperature ° C (° F)

1.7 (35)

1.7 (35)

 

1.7 (35)

 

1.7 (35)

1.7 (35)

Weight Kg (lbs)

3650

3650

 

3650

 

5933

5933

 

(8030)

(8030)

 

(8030)

 

(13,080)

(13,080)

Maximum pressure barg (psig)

10 (145)

10 (145)

 

10 (145)

 

10 (145)

10 (145)

Minimum pressure barg (psig)

4.5 (65)

4.5 (65)

 

4.5 (65)

 

4.5 (65)

4.5 (65)

Coolant capacity litres (US gal)

95 (25)

95 (25)

 

95 (25)

 

152 (40)

152 (40)

HAT switch setting ° C (° F)

120 (248)

120 (248)

 

120 (248)

 

120 (248)

120 (248)

Performance **

 

 

 

 

 

 

 

Flow at 7.5 Barg (m3/min)

26.2

31.1

 

 

Flow at 8.5 Barg (m3/min)

24.2

29.6

 

 

Flow at 10 Barg (m3/min)

23.1

27.2

 

 

Flow at 14 Barg (m3/min)

18.4

22.2

 

 

Flow at 100 psig (cfm)

 

1100

 

1380

1690

Flow at 125 psig (cfm)

 

990

 

1249

1527

Flow at 140 psig (cfm)

 

924

 

1167

1430

Flow at 200 psig (cfm)

 

735

 

Air Cooling System

 

 

 

 

 

 

 

Cooling air flow m3/min (cfm)

382

382

 

382

 

679

679

 

(13500)

(13500)

 

(13500)

 

(24000)

(24000)

Maximum ΔP in air ducts Pa (inch WG)

124 (0.5)

124 (0.5)

 

124 (0.5)

 

62 (0.25)

62 (0.25)

Compressed air outlet ΔT ° C (° F)

8 (15)

8 (15)

 

8 (15)

 

8 (15)

8 (15)

Water Cooling System

 

 

 

 

 

 

 

Cooling (clean) water flow l/min (US gallon/

110/87

125/106

 

125/106

 

352

352

min) @

(29/23)

(33/28)

 

(33/28)

 

(93)

(93)

10° C (50° F) / 32° C (90° F) ****

 

 

 

 

 

 

 

 

 

Maximum ΔP in air ducts Pa (inch WG)

62 (0.25)

62 (0.25)

 

62 (0.25)

 

62 (0.25)

62 (0.25)

Compressed air outlet ΔT ° C (° F)

14 (25)

14 (25)

 

14 (25)

 

14 (25)

14 (25)

Main Power Circuit A/C (W/C) ***

 

 

 

 

 

 

 

Package full load current at 400V (A) **

251 (239)

301 (289)

 

 

Package full load current at 460V (A) **

 

255 (245)

 

335 (313)

406 (384)

Package full load current at 575V (A) **

 

210 (202)

 

267 (250)

324 (307)

Max fuse size @ 380V − 415V (A)

350

450

 

 

Max fuse size @ 440V − 480V (A)

 

350

 

600

Max fuse size @ 550V − 575V (A)

 

300

 

500

Fuse type

Fast acting class J, T or semiconductor type, current limiting interrupt

 

 

rating 200, 000 Amps RMS SYM.

 

Heater Circuit

 

 

 

 

 

 

 

110V Single Phase Rating (A)

4

4

 

4

 

4

4

230V Single Phase Rating (A)

4

4

 

4

 

4

4

Fuse type

 

 

General purpose

 

 

 

 

 

 

 

 

 

 

*In accordance with PNEUROP PN8NTC2.3

**Tolerances in accordance with ISO 1217

***Always apply local electrical codes for sizing cables and fusing. In the absence of local codes the minimum cable size should be calculated on basis of mean package full load current X1.25 (i.e. 25% margin)

****Cooling water flow for N250H and N300H are @ 46 deg C (115 deg F)

32IRN37 - 160K - CC & IRN50 - 200H -CC & IRN75 - 160K - 2S & IRN100 - 200H - 2S & IRN 250 - 300H - 2S