Replacing the Projection Lamp
CAUTION:
•Potential hazard of glass particles if lamp has ruptured. Please have Sharp Authorized LCD Projector Dealer or Service Center replace lamp if rupture occurs.
•Do not remove the lamp cage directly after operation of the projector. The lamp may be extremely hot. Wait at least one hour after the power cord is disconnected to allow the surface of the lamp cage to fully cool before removing the lamp cage.
The rated lamp life is about 1000 hours. The rated lamp life is the average life of the lamps produced and tested (under the test conditions of our company). However, it may become shorter depending on the conditions of usage.
After the lamp has been operating for 1000 hours or longer, the STATUS indicator on the control panel will light and the “LAMP USAGE” icon which shows hours of total lamp usage will be displayed on the screen. When this happens, turn off the unit and replace the lamp cage with a new one. The unit will not turn on after 1100 hours. (It will go off if it is in use.)
Removing and installing the lamp unit
CAUTION
•Be sure to remove the lamp cage by the handle. Be sure not to touch the glass surface of the lamp cage or the inside of the projector.
•Do not loosen any screws except for those mentioned in the instructions below. There is danger of electric shock.
•To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below.
1 | Turn off the power. |
| Disconnect the power | Open the lamp cage | |
|
| 2 cord. | 3 cover. | ||
Press the POWER ON/OFF button. | Unplug the power cord from the | Turn over the projector and un- | |||
Wait until the cooling fan stops. | AC socket. Wait at least one hour | fasten the user service screw that | |||
|
| ON/OFF | after power cord is disconnected. | secures the lamp cage cover. | |
|
|
|
| Then open the cover in the direc- | |
|
|
|
|
| |
|
|
|
|
| tion of the arrow. |
|
| or |
|
|
|
|
|
|
|
| User service screw |
|
| ON/OFF |
|
|
|
| MOUSE | ON/OFF |
|
|
|
|
| MENU |
|
|
|
| VIDEO | COMPUTER |
|
|
|
|
|
|
|
| |
| DIGITAL MULTIMEDIA |
|
|
| |
|
| PROJECTOR |
|
|
|
| Remove the lamp | 5 | Replace the lamp cage | Close the lamp cage | |
4 cage. |
| (after changing the lamp). | 6 cover. | ||
Unfasten the three securing | Press the lamp cage firmly into | Close the lamp cage cover in the | |||
screws on the lamp cage. Hold | the lamp cage compartment. | direction of the arrow. Then | |||
the lamp cage by the handle and | Fasten the securing screws. | fasten the user service screw. | |||
pull it upward. |
|
|
|
| |
|
| Securing |
|
| User service |
|
| screws |
|
| screw |
Others
•Reset the lamp usage timer after replacing the lamp. See page 29 for information.
•When the lamp usage timer reaches 1100 hours, it becomes impossible to turn on the power and menus are not displayed. In such a case, see “When the lamp usage timer has exceeds 1100 hours and the unit will not turn on” on page 29.
•Obtain a replacement lamp cage at the store where the unit was purchased. Please specify the following information when ordering a replacement lamp cartridge: