RS-232C command table
<How to read the command table>
Command: | Command field (See page 40.) | |
Direction: | W | When the “Parameter” is set in the parameter field (see page 40), the |
|
| command functions as described under “Control/Response Contents”. |
| R | The returned value indicated under “Reply” can be obtained by setting |
|
| “????”, “___?” or “???+” (repeater control) in the parameter field (see page |
|
| 40). |
Parameter: | Parameter field (See page 40.) | |
Reply: | Response (Returned value) |
* A circle indicates commands which can be used in power standby mode.
ENGLISH
Power control/Input selection, etc.
*can be used in standby mode
Control item | Command | Direction | Parameter | Reply | Control/Response contents | * | ||
|
|
|
|
|
|
|
|
|
|
| W | 0 |
|
| Switches to standby. |
|
|
|
|
|
|
|
|
|
| |
|
| 1 |
|
| Returns from standby. |
|
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
Power Setting | POWR |
|
| 0 | Standby mode |
| Yes | |
|
|
|
|
|
|
|
|
|
|
| R |
| 1 | Normal mode |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| 2 | Waiting mode |
|
| |
|
|
|
|
|
|
|
|
|
|
|
| 0 |
|
| Toggle change |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
|
| INPUT1 : DVI |
|
|
|
|
|
|
|
|
|
|
|
|
| W | 2 |
|
| INPUT2 : RGB |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3 |
|
| INPUT3 : Component |
|
|
|
|
|
|
|
|
|
|
|
Input Selection | INPS |
| 4 |
|
| INPUT4 : |
| Yes |
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | INPUT1 : DVI |
|
| |
|
|
|
|
|
|
|
| |
|
| R |
| 2 | INPUT2 : RGB |
|
| |
|
|
|
|
|
|
|
| |
|
|
|
| 3 | INPUT3 : Component |
|
| |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
|
|
|
| 4 | INPUT4 : |
|
| |
|
|
|
|
|
|
|
|
|
47 E