Sharp PN-Y475, PN-Y555, PN-Y425 37 E, Controlling the Monitor with a PC RS-232C SETUP menu, Others

Models: PN-Y555

1 49
Download 49 pages 9.07 Kb
Page 37
Image 37
Controlling the Monitor with a PC (RS-232C)

Controlling the Monitor with a PC (RS-232C)

SETUP menu

 

Function

Command

Direction

Parameter

Reply

Control/Response contents

*

DATE/TIME SETTING

DATE

WR

AABBCCDDEE

AABBCCDDEE

AA: Year, BB: Month, CC: Day, DD: Hour, EE: Minute

 

 

 

 

 

 

 

 

 

 

ID SETTING

 

ID NO.SETTING

IDST

W

0-25

 

Sets the monitor’s ID number. (“0” means “no ID number”.)

 

 

 

 

 

R

 

0-25

Returns the monitor’s ID number.

 

 

 

ID NO. SETTING

IDSL

W

1-25

 

Sets a monitor ID number.

 

 

 

(ONCE)

 

 

 

 

This ID number is only effective for the command immediately after this

 

 

 

 

 

 

 

 

command.

 

 

 

 

 

 

0

 

Clears the ID number if one has been designated.

 

 

 

ID NO. SETTING

IDLK

W

1-25

 

Sets a monitor ID number.

 

 

 

(SUBSEQUENT)

 

 

 

 

This ID number is effective for the next and all subsequent commands after this

 

 

 

 

 

 

 

 

command.

 

 

 

 

 

 

0

 

Clears the ID number if one has been designated.

 

 

 

 

 

 

 

 

 

 

MULTI

 

ENLARGE

ENLG

WR

0-1

0-1

0: OFF, 1: ON

 

 

 

ENLARGE MODE

EMHV

WR

11-55

11-55

1 x 1 (OFF) to 5 x 5 (“m x n” is expressed as “mn”, where m and n are the

 

 

 

 

 

 

 

numbers of monitors specified for the longest direction and the shortest direction

 

 

 

 

 

 

 

respectively.)

 

 

 

IMAGE POSITION

EPHV

WR

11-55

11-55

Specifies values in the order of IMAGE POSITION IN LONGEST/ SHORTEST

 

 

 

(M x N)

 

 

 

 

DIRECTION.

 

 

 

BEZEL ADJUST

BZCO

WR

0-1

0-1

0: OFF, 1: ON

 

 

 

ENLARGE/

ESHV

WR

XXYY

XXYY

XX: ENLARGE MODE (Same as EMHV), YY: IMAGE POSITION (Same as

 

 

 

IMAGE POSITION

 

 

 

 

EPHV)

 

 

 

SETTING

 

 

 

 

 

 

THERMAL SENSOR SETTING

STDR

WR

0-1

0-1

0: LANDSCAPE, 1: PORTRAIT

 

ADJUSTMENT

 

MONITOR

ALCM

WR

0-1, 3

0-1, 3

0: UNLOCKED, 1: LOCK ALL, 3: LOCK EXCEPT POWER

 

LOCK

 

BUTTONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REMOTE

ALCR

WR

0-3

0-3

0: UNLOCKED, 1: LOCK ALL, 2: LOCK EXCEPT VOLUME,

 

 

 

CONTROL

 

 

 

 

3: LOCK EXCEPT POWER

 

Others

 

Function

Command

Direction

Parameter

Reply

Control/Response contents

*

 

 

 

 

 

 

 

 

 

VOLUME

 

 

VOLM

WR

0-31

0-31

 

MUTE

 

 

MUTE

WR

0-1

0-1

0: OFF, 1: ON

-

INFORMATION

 

MODEL

INF1

R

 

Value

 

 

 

 

SERIAL NO

SRNO

R

 

Value

 

 

TEMPERATURE SENSOR

DSTA

R

 

0

Internal temperature normal

 

 

 

 

 

 

 

1

Internal temperature abnormal has occurred and the monitor is in standby mode

 

 

 

 

 

 

 

2

Internal temperature abnormal occurred (To delete the information of temperature

 

 

 

 

 

 

 

 

abnormal, turn off the main power.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Internal temperature abnormal has occurred and backlight brightness is dimmed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Temperature sensor abnormal

 

 

 

 

 

 

 

 

TEMPERATURE ACQUISITION

ERRT

R

 

Value

Returns the temperature at the temperature sensors in the following format.

 

 

 

 

 

 

 

 

[Sensor 1]

 

CAUSE OF LAST STANDBY MODE

STCA

W

0

 

Initialization

 

 

 

 

R

 

0

No detectable error has occurred

 

 

 

 

 

 

 

 

 

 

 

 

1

Standby mode by POWER button

 

 

 

 

 

 

 

3

Standby mode by RS-232C or LAN

 

 

 

 

 

 

 

4

Input signal waiting mode by No Signal

 

 

 

 

 

 

 

6

Standby mode by abnormal temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Standby mode by SCHEDULE setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

Standby mode by OFF IF NO OPERATION setting

 

 

 

 

 

 

 

 

 

 

LAN SETUP

 

USERNAME

USER

WR

XXXXXXXX

XXXXXXXX

X: Eight characters or less; half-width alphanumeric characters, "-", and "_".

 

 

 

 

 

 

 

 

(The field can be left blank, but spaces cannot be entered.)

 

 

 

PASSWORD

PASS

WR

XXXXXXXX

XXXXXXXX

X: Eight characters or less; half-width alphanumeric characters, "-", and "_".

 

 

 

 

 

 

 

 

(The field can be left blank, but spaces cannot be entered.)

 

TIPS

• Some menu setting items do not have a command. Set with the remote control during installation.

37 E

Page 37
Image 37
Sharp PN-Y475, PN-Y555, PN-Y425 operation manual 37 E, Controlling the Monitor with a PC RS-232C SETUP menu, Others