Sharp PN-Y555, PN-Y475, PN-Y425 operation manual 33 E, nResponse code format, nID SETTING

Models: PN-Y555

1 49
Download 49 pages 9.07 Kb
Page 33
Image 33
nResponse code format

nResponse code format

When a command has been executed correctly

O

K

 

 

 

Return code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0DH, 0AH)

A response is returned after a command is executed. * If an ID number has been assigned

 

 

 

Space (20H)

 

Return code

 

 

 

 

(0DH, 0AH)

 

 

 

 

 

 

 

 

 

 

O

K

SPC

0

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID number of responding monitor

When a command has not been executed

ER R Controlling the Monitor with a PC (RS-232C)nID SETTING33 EManual background Return code (0DH, 0AH)

*If an ID number has been assigned

 

Space (20H)

Return code

 

 

 

 

 

(0DH, 0AH)

 

 

 

 

 

 

 

 

 

 

E

R

R

SPC

0

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID number

TIPS

“ERR” is returned when there is no relevant command or when the command cannot be used in the current state of the monitor.

If communication has not been established for reasons such as a bad connection between the PC and monitor, nothing is returned (not even ERR).

“ERR” may be returned when a command cannot be received correctly due to interference from the surrounding environment.

Please ensure that the system or software retries the command if this occurs.

If no monitor has been assigned the designated ID number

(e.g. if the command IDSL0002 Manual backgroundManual backgroundManual background is used, but no monitor with ID number: 2 is found), no response is returned.

If execution of the command is taking some time

W

A

I

T

 

 

 

 

Return code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0DH, 0AH)

Controlling the Monitor with a PC (RS-232C)

nCommunication interval

After OK or ERR is returned, you must send the following commands.

To set a timeout for the command response, specify 10 seconds or longer.

When connecting multiple monitors in a daisy chain, set the timeout to at least the product of the monitor’s position from the computer multiplied by 10 seconds.

Example) 3rd monitor from computer: 30 seconds or longer.

Provide an interval of 100 ms or more between the command response and the transmission of the next command.

VOLM0020

OK

Interval of 100 ms or more

INPS0001

WAIT

OK

TIPS

When turning the power on while the POWER ON DELAY function is in use, set the timeout period to the POWER ON

DELAY period + 10 seconds or longer.

Advanced operation

This section explains commands for daisy chain connection. The basic communication procedure is the same as in the “One-to-one connection with a PC” section.

nID SETTING

You can assign a unique ID number to each monitor (see page 27). This allows you to control a particular monitor in a daisy chain of monitors.

You can assign ID numbers either from the menu screen or from the PC using RS-232 cable.

[Example]

ID number: 1 ID number: 2 ID number: 3 ID number: 4

When the following commands are used, “WAIT” is returned. In this case, a value will be returned if you wait a while. Do not send any command during this period.

No ID number is attached to WAIT response.

Commands which return WAIT:

1.When repeater control is used

2.When an IDSL or IDLK command is used

3.When one of the following commands is used: RSET, INPS, ASNC, WIDE, POWR, EMHV, EPHV, ESHV,

ENLG

If monitors are connected as shown above, you can execute commands like “Set the volume of the monitor with ID 4 to 20”.

When designating ID numbers for a set of monitors linked in a daisy chain, you should basically avoid any duplication of ID numbers.

ID numbers do not have to be assigned in ascending order starting from the PC. They can also be connected as shown below.

[Example]

ID number: 3 ID number: 2 ID number: 4 ID number: 1

33 E

Page 33
Image 33
Sharp PN-Y555 33 E, nResponse code format, Controlling the Monitor with a PC RS-232C nCommunication interval, nID SETTING