U N P A C K I N G A N D I N S T A L L A T I O N I N S T R U C T I O N S

3 ELECTRICAL GROUNDING INSTRUCTIONS

This appliance must be grounded. This oven is equipped with a cord having a grounding wire with a grounding plug. It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local codes and ordinances. In the event of an electrical short circuit, grounding reduces risk of electric shock by providing an escape wire for the electric current.

WARNING - Improper use of the grounding plug can result in a risk of electric shock.

Electrical Requirements

The oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY

CIRCUMSTANCES CUT OR REMOVE THE GROUNDING PIN FROM THE PLUG.

The Power Supply Cord and plug must be connected to a separate 120 Volt AC, 60 Hz, 15 Amp, or more branch circuit, single grounded receptacle. The receptacle should be located inside the cabinet directly above the Microwave Oven mounting location as shown in Figure 2.

NOTE:

1.If you have any questions about the grounding or electrical instructions, consult a qualified electrician or serviceperson.

2. Neither Sharp nor the dealer can accept any liability for

Figure 2

damage to the oven or personal injury resulting from failure to

 

observe the correct electrical connection procedures.

 

Radio or TV Interference

Should there be any interference caused by the microwave oven to your radio or TV, check that the microwave oven is on a different electrical circuit, relocate the radio or TV as far away from the oven as feasible or check position and signal of receiving antenna.

Ground

Receptacle

Opening for

Power Cord

4 HOOD EXHAUST DUCT

When the hood is vented to the outside, a hood exhaust duct is required. All ductwork must be metal; absolutely do not use plastic duct. Check that all connections are made securely. Please read the following carefully:

Exhaust connection: The hood exhaust has been designed to connect to a standard 3-1/4” X 10” rectangular duct. If round duct is required, a rectangular-to-round adapter must be used.

Rear exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align the exhaust with the space between the studs, or wall should be prepared at the time it is constructed by leaving enough space between wall studs to accommodate exhaust.

Maximum duct length: For satisfactory air movement, the total duct length of 3-1/4” X 10” rectangular or 6” diameter round duct should not exceed 140 feet.

Elbows, adapters, wall caps, roof caps, etc. present additional resistance to air flow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total length, add the equivalent lengths of all transitions and adapters plus the length of all straight duct sections. Figure 3 shows the approximate feet of equivalent length of some typical ductwork parts. Use the values in parentheses for calculating air flow resistance equivalent, which should total less than 140 feet.

Figure 3

7

Page 7
Image 7
Sharp R-1405, R-1406 manual Electrical Grounding Instructions, Hood Exhaust Duct

R-1405, R-1406, R-1406 specifications

The Sharp R-1406 and R-1405 are models from a renowned line of microwave ovens that combine style, functionality, and advanced technology to meet modern kitchen needs. Both appliances are designed to deliver convenience and efficiency, making them an essential tool for meal preparation.

Starting with the Sharp R-1406, this model boasts a sleek design that complements any kitchen décor. It features a compact size, which makes it ideal for small spaces while still offering a generous interior capacity. One of the standout characteristics of the R-1406 is its user-friendly control panel, which comes with easily accessible buttons for setting the cooking time and power levels. The microwave utilizes a turntable to ensure even cooking and heating of food, which is a critical feature for achieving perfect results with every dish.

In terms of technology, the R-1406 is equipped with a range of pre-programmed settings that cater to various cooking needs. These presets allow users to quickly reheat leftovers, defrost frozen items, or cook specific dishes without needing to determine the cooking time manually. The appliance employs a powerful magnetron that ensures quick and efficient microwave energy production, resulting in faster cooking times. Additionally, the R-1406 features a user-friendly digital display that makes monitoring cooking progress easy.

The Sharp R-1405, while similar in design, offers its unique set of features tailored to different cooking preferences. This model also prioritizes space-saving design but benefits from enhanced energy efficiency. The R-1405 includes a smart inverter technology that provides a consistent cooking power, allowing for more even heating and defrosting compared to conventional microwave ovens. This is particularly useful when preparing delicate foods, ensuring they are heated consistently without the risk of cooking certain areas too much.

Both models come with safety features such as child locks and automatic shut-off, promoting safe use in households with children. They are built with durable materials designed to withstand the rigors of daily cooking while ensuring easy cleaning. The combination of user-friendly features, innovative technology, and sleek design makes both the Sharp R-1406 and R-1405 excellent choices for anyone looking to enhance their cooking experience with reliable microwave solutions. They exemplify Sharp's commitment to quality and efficiency in home appliances.