SERVICE CALL CHECK

Please check the following before calling for service:

1.Place one cup of water in a glass measuring cup in the oven and close the door securely. Operata the oven for two minutes a HIGH 100%.

A. Does the light ceme on in the oven?

YES

B. Does the cooling fan work?

YES

(Put your hand over the top ventilation openings.)

 

C. Does the turntable rotate when the TURNTABLE ON/OFF

pad is touched and TURNTABLE ON is in the display? YES (It is normal for the turntable to turn in either direction when TURNTABLE ON is in the display.)

 

D. Is the water in the oven warm?

 

YES

 

2.

Remove the water from the oven and program:

I CONVEC

I

450°F

 

 

 

 

START

 

A. Do CONV and COOK light?

 

YES

 

 

B. After the oven shuts off, is the inside of the oven

hot?

YES

 

NO

NO

NO

NO

NO

NO

If "NO" is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit breaker, If either or both are not functioning properly, CONTACT YOUR NEAREST SHARP AUTHORIZED SERVICER. A

microwave oven should never be serviced by a "do -lt-yeurself"repair person.

NOTE: If time appearing in the display is ceunting down very rapidly, check Demonstration Mode on page 24 and cancel.

SPECIFICATIONS

AG Line Voltage:

AC Power Required:

Output Power:

Microwave

Convection Heater:

Frequency:

Outside Dimensions:

Cavity Dimensions:

Oven Capacity:

Cooking Uniformity:

Weight:

R-1850A I R-1851A I R-1852A

Single phase 120V, 60Hz, AC only 1600 watts 13.2 amps.

850 watts' (IEG-705-1988 Test Procedure)

1400 watts

2450 MHz

2915/16" (W) x 16 11132" (H) x 15 9132" (D) 171/8" (W) x 81/t6" (H) x 1313/16" (D)

1.1 cu. It.

Turntable & Stirrer Fan Approx. 71 Ibs.

·The International Electrotschnical Commission's standardized method for measuring output wattage. This test method is widely recognized.

In compliance with standards set by:

FCC - Federal Communications Commission Authorized.

DHHS - Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J.

®-This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.