Flow Chart of Troubleshooting

10-1-5. Microphone Part

Micro-phone does not work

Is the connection status of

HDC300 O.K?

YES

Check the DC bias voltage on

Mic path.

The voltage of C406 is about 2.2V±10%?

YES

Is microphone OK?

YES

END

NO

NO

NO

Reconnect connector of HDC300

Solder the microphone again or Replace

R406, R415, R418, R425

Check UCD301

10-11