XEA-201 Reset
There are 2 resets for the
The initial procedure is below. You should not lose your programming information doing this reset.
•Unplug from the electrical outlet
•Wait over 1 minute for unit to discharge
•Put the register in PGM mode
•While holding down the “feed” key, plug in the unit.
If this procedure does not reset unit please try the following. *
•Make sure register is plugged in
•Put register in REG mode
•Take out the batteries
•Unplug the register from the electrical outlet
•Wait 1 minute for unit to discharge
•Plug unit back in
*Note: This is considered the Master Reset and should reset the unit to factory settings.
XEA-401 reset
There are 2 resets for the
The first procedure is as follows: this should always be done first. You should not lose your programming with this reset.
•Unplug the unit from the electrical outlet
•Set the mode switch to PGM position
•While holding down both “journal feed” key and “Receipt feed” key, plug unit back in.
If this procedure does not work, proceed with the Master Reset below.*
•Unplug unit from electrical outlet
•Set the mode switch to PGM mode
•While holding down both the “journal feed” key and the “CL” key, plug the unit back in.
*Note: This procedure is considered the Master Reset and should reset to factory settings.
3