Sharp XR-30S RS-232C Specifications and Command Settings, Computer control, Basic format, Info

Models: XR-30S XR-40X XR-30X

1 71
Download 71 pages 57.84 Kb
Page 59
Image 59
RS-232C Specifications and Command Settings

RS-232C Specifications and Command Settings

Computer control

A computer can be used to control the projector by connecting an RS-232C serial control cable (cross type, sold separately) to the projector. (See page 24 for connection.)

Communication conditions

Set the serial port settings of the computer to match that of the table.

Signal format: Conforms to RS-232C standard.

Parity bit: None

Baud rate: * 9,600 bps/115,200 bps

Stop bit: 1 bit

Data length: 8 bits

Flow control: None

* Set the projector’s baud rate to the same rate as used by the computer.

Basic format

Commands from the computer are sent in the following order: command, parameter, and return code. After the projector processes the command from the computer, it sends a response code to the computer.

Command format

C1 C2

C3

C4

P1

P2

P3

P4

 

 

 

 

 

Return code (0DH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command 4-digit

Parameter 4-digit

 

 

 

 

Response code format

 

 

 

 

 

 

 

 

 

 

 

Normal response

 

Problem response (communication error or incorrect command)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

K

 

 

Return code (0DH)

 

 

 

E

R

R

 

Return code (0DH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Computer control Info

When controlling the projector using RS-232C commands from a computer, wait for at least 30 seconds after the power has been turned on, and then transmit the commands.

After sending an input selection command and then receiving an “OK” response code, the projector may take some time to process the command. Please be aware that commands should be sent at intervals of at least 5 seconds.

When more than one code is being sent, send each command only after the response code for the previous command from the projector is verified.

“POWR????” “TABN _ _ _ 1” “TLPS _ _ _ 1” “TPOW _ _ _ 1” “TLPN _ _ _ 1” “TLTT _ _ _ 1” “TLTL _ _ _ 1” “TNAM _ _ _ 1” “MNRD _ _ _ 1” “PJN0 _ _ _ 1”

-When the projector receives the special commands shown above:

*The on-screen display will not disappear.

*The “Auto Power Off” timer will not be reset.

-The special commands are available for applications that require continuous polling.

Communication conditions Note

If an underbar (_) appears in the parameter column, enter a space.

If an asterisk (*) appears in the parameter column, enter a value in the range indicated in brackets under Control Contents.

*1

For setting the projector name, send the commands in the order of PJN1, PJN2 and PJN3.

 

*2 This command should be sent only after the “IRGB _ _ _ 2” command is sent and an “OK” response

 

 

code is received.

 

*3

The Lamp Timer Reset command is available only in standby mode.

Appendix

 

 

55

Page 59
Image 59
Sharp XR-30S RS-232C Specifications and Command Settings, Computer control, Communication conditions, Basic format, Info