Maintenance and Service

3.Vacuum the bottom of the firebox thoroughly. Carefully clean off any dust on the logs and remove any lint from the main burner and pilot burner.

4.After carefully replacing the log and embers in their correct positions (see Secondary Installation - Installation of Log Set and Embers), and the door has been resealed, re-light the pilot, following the instructions on the lighting label attached to the unit.

CLEANING PLATED SURFACES:

It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes. To avoid this, give the face a quick wipe with denatured alcohol on a soft cloth BEFORE lighting the fireplace. Never clean the face when it is not cool. Do not use other cleaners as they may leave a residue, which can become permanently etched into the surface.

BURNER REMOVAL:

The burner may need to be removed for a few reasons, including cleaning under the burner, converting the unit to a different gas type, or to replace the burner altogether. Proceed only when the unit has completely cooled down.

1.Remove the door as shown in the MAINTENANCE AND SERVICE - OPENING THE DOOR.

2.Remove the two (2) T-20 screws that hold

the burner in place; one (1) at each of the rear burner (see Figure 7).

3. Lift the burner assembly (both the front and rear burners) straight up then out.

To re-install the burner follow steps 1-3 in

 

reverse. When placing the burner back in the

 

unit ensure that the venturi box under the

Figure 7: Screws holding Burner.

burner is lined up.

REPLACING THE BLOWER:

 

1.

Turn the unit off, allow it to cool down completely, and

 

remove the door as shown in the MAINTENANCE AND SERVICE

 

- OPENING THE DOOR..

2. Remove the log set and brick liner.

3.

Remove the burner tray assembly, see MAINTENANCE AND

 

SERVICE - BURNER REMOVAL.

4.

Remove the four (4) 5/16” bolts that hold the blower

 

mounting plate to the back firewall. Use a light lubricating

 

oil on screws before removal.

5.

Carefully pull the blower assembly into the firebox (see

 

Figure 7) disconnect the blower leads from the harness and

 

remove blower.

6.

To re-install, check mounting plate gasket if damaged

 

replace with new one and reverse steps 1 through 4. Refer

Figure 8: Blower (Fan) Removal.

to “SECONDARY INSTALLATION - LOG SET AND EMBERS INSTALLATION”.

9

Page 9
Image 9
Sherwood EG40 DV owner manual Burner is lined up