Multiplexer Driver Developer’s Guide

4.2 Settings Stored in the Windows Registry

The following Registry values in the path

s

HKLM \System\CurrentControlSet\Services\winmux2k\Parameters are used to configure the TRACE out- puts. These values are only valid for the debug version of the device driver.

Table 7: Registry values for trace outputs

Values

Data (Example)

Properties

 

 

 

 

DebugBaud

57600

Baud rate: used if DebugPort is different from 0.

 

 

 

DebugMask

0x0000003

DebugMask determine, which reports from the device driver

 

 

are printed to the DebugPort.

 

 

Masks:

 

 

 

0x0000001

Errors

 

 

0x0000002

Warnings

 

 

0x0000004

Information’s

 

 

0x0000008 PnP

 

 

0x0000010 Power management

 

 

0x0000020

Data control commands

 

 

0x0000040

Open/Close/Cleanup

 

 

0x0000080

Dispatch Device Control

 

 

0x0000100

Dispatch Read/Write

 

 

0x0000200

Submit control requests

 

 

0x0004000 framed data read/write

 

 

0x0008000 frequently traces submit/wrsupport

 

 

The mask 0x7 means, that all three traces are on.

 

 

The next masks are only for driver checks and represent

 

 

internal variables and states of the serial Multiplexer Device

 

 

driver.

 

 

 

0x0001 0000 Frame information, send and receive

 

 

0x0002 0000 Frame information, HDLC

 

 

0x0004 0000 Status information from virtual channels

 

 

0x0008 0000 Status information from Multiplexer control

 

 

channel

 

 

 

0x0010 0000 Output Names from WinMux2k functions

 

 

0x1000 0000 traces how and because a Request completed

 

 

0x2000 0000 traces V.24 signals and change of these sig-

 

 

nals

 

 

 

0x4000 0000 traces, in which state is the parser for scanning

 

 

the +++ sequence

 

 

0x8000 0000 traces states for scanning a Frame

 

 

 

DebugPort

0x0

0 Output from the driver is redirected to the kernel debugger.

 

 

(default value)

 

 

1...4: Output is redirected to a COM port

 

 

 

 