Command *1)

Activated by input

Order on the

 

No.:

terminal board

XXppppSMSNOA1Vnumber

IO1

1

XXppppSMSNOB1Vnumber

IO1

1

XXppppSMSNOA2Vnumber

IO2

2

XXppppSMSNOB2Vnumber

IO2

2

XXppppSMSNOA3Vnumber

IO3

3

XXppppSMSNOB3Vnumber

IO3

3

XXppppSMSNOA4Vnumber

IO4

4

XXppppSMSNOB4Vnumber

IO4

4

XXppppSMSNOA5Vnumber

IO5

5

XXppppSMSNOB5Vnumber

IO5

5

XXppppSMSNOA6Vnumber

IO6

6

XXppppSMSNOB6Vnumber

IO6

6

XXppppSMSNOB7Vnumber

IO7

8

XXppppSMSNOB7Vnumber

IO7

8

XXppppSMSNOB8Vnumber

IO8

9

XXppppSMSNOB8Vnumber

IO8

9

pppp

Four digits of current PIN

Number *2)

Maximum 14 digits of cell phone number

*1) The space is between key word of command and number

*2) Number can be entered in national format – e.g. 606445566 but also in international format – e.g. +420606445566.

If you want to deactivate the number set command without number – tm. e.g. XXppppSMSNOA3 without further parameters.

4.10. OUT – Set-up of Level of Outputs by SMS messages

Required logical level of outputs No. 1 to 8 can be set by incoming SMS message. If output is set to logical value 0 it is not possible to activate it as input.

Command *1)

Output

Order on the

 

 

terminal board

XXppppOUT1Vy

IO1

1

XXppppOUT2Vy

IO2

2

XXppppOUT3Vy

IO3

3

XXppppOUT4Vy

IO4

4

XXppppOUT5Vy

IO5

5

XXppppOUT6Vy

IO6

6

XXppppOUT7Vy

IO7

8

XXppppOUT8Vy

IO8

9

pppp

Four digits of current PIN

y

Figure 0 or 1 determines logical level of output

 

By sending value 0 output is set to 0V

 

By sending value 1 output is set to 4-5V

*1) The space is between key word of command and value of parameter “y”

All outputs are set to logical level 1 (4–5 V) from production.

Inputs can be therefore activated.

15

Page 15
Image 15
Siemens M35 or S35, C35i manual IO1, IO2, IO3, IO4, IO5, IO6, IO7, IO8