Hardware Components of the SIMATIC Box PC 620
3-12 SIMATIC Box PC 620 Operating Manual
C79000-Z7076-C638-04
Information on the LS120-disk drive

Restrictions

P Tools under STEP 5
Data cannot be edited in PCP/M format on the LS120-drive using P Tools under
STEP 5.
Authorization with Authors Vx.x
In order to authorize STEP 5 and other SIMATIC components, use AuthorsW.
When using PCs start the taskbar under Start > Simatic > AuthorsW.

Settings in Setup

In order to put the LS120-drive into operation the following settings are valid.
These are the default settings for the device.
To open the Setup menu, press function key F2 during the boot sequence. Make
the following settings in Setup:
1. In the “Main” menu, set Diskette A: to “Disable”.
2. In the “Main” menu under Boot Options:
Set the boot sequence as follows:
1 Removable Devices
2 Hard Drive
3 ATAPI CD-ROM Drive
4 Diskette Drive
3. In the “Advanced” menu, set Floppy-Disk-Controller to “Disable”.
4. Boot the device with Save Changes & Exit”.
With these settings the LS120-drive can be addressed in the same way as the
1,44 Mbyte floppy-disk drive previously installed.

Usage notes for LS 120 Superdisks

In Floppy disks up to 1.44 Mbytes as well as Superdisks up to 120 Mbytes can be
used in LS120-drives.
Track density for Superdisks is 10 mm compared with the 120 mm of conventional
disks.
The LS120 recognizes when a Superdisk is in the drive and switches to the higher
capacity. With conventional disks, a capacity of 1.44 Mbytes or 720 Kbytes can be
reached.
Due to their higher storage capacity, Superdisks are more sensitive to dirt, tempe-
rature and shock than conventional diskettes.