Error Diagnosis and Reinstallation
6-2 SIMATIC Box PC 620 Operating Manual
C79000-Z7076-C638-04
6.1 Problems When Using Modules from Other Manufacturers

Error Display

The PC crashes during power up.

Cause

The following causes are possible:
Double assignment of I/O addresses
Double assignment of hardware interrupts and/or DMA channels
Signal frequencies or signal levels are not met
Different connector assignments

Remedy

Check your computer configuration:
If the computer configuration is the same as when your PC was delivered,
please contact your technical support team (Chapter 8).
If the computer configuration has changed, re-establish the configuration you
had when your PC was delivered. Remove any modules from other
manufacturers. Perform a complete restart on your PC.
If the PC still crashes, you must contact your technical support team.
If the error no longer occurs, the module you used from another
manufacturer was the cause of the fault. Replace this module with a
Siemens module, or contact the module supplier.