PPP over Ethernet (PPPoE) Mode

PPP over Ethernet (PPPoE) Mode

Dynamic Public IP

Default Private IP

assigned by BRAS

192.168.1.1

ISP

 

 

 

192.168.1.3

 

 

 

 

(Internet Service Provider)

STM-1

Loop

 

 

 

 

 

 

 

 

 

 

Ethernet

BRAS

 

 

ADSL

Hub

 

DSLAM

 

 

Router

 

AAA

 

 

 

192.168.1.2

 

 

 

 

RDAIUS

 

 

 

 

Server

 

 

 

PC(S)

 

 

 

 

*BRAS: Broadband

PPP over Ethernet

 

 

 

 

 

Remote Access Server

PPPoE+NAT+DHCP

 

 

 

 

 

 

on Private LAN

 

 

Description:

In this deployment environment, the PPPoE session is between the ADSL WAN interface and BRAS. The ADSL Router gets a public IP address from BRAS when connecting to DSLAM. The multiple client PCs will get private IP address from the DHCP server enabled on private LAN. The enabled NAT mechanism will translate the IP information for clients to access the Internet.

Configuration:

1.Start up your browser and type 192.168.1.1 as the address to enter this ADSL web-based manager.

2.Go to Quick Start -Quick Setup. Uncheck Auto Scan Internet Connection (PVC). Type in the VCI and VPI value. Then click the Next button. eg:

VPI – 0 VCI – 39

3.On the Configure Internet Connection -Connection Type page, select the PPP over Ethernet (PPPoE) then click the Next button.

4.In the WAN IP Settings page, select Obtain an IP address automatically and check Enable NAT box. Click Next.

5.In the PPP Username and Password page, enter the PPP username and password that you got from your ISP. Select Dial on Demand and type in the number for inactivity timeout. The default is 20. Or select Always on. Then click Next.

6.In the Configure LAN side Settings page, type in the IP address and subnet mask for your LAN. Check DHCP Server on box. And type in the start and end points. Then type in the leased time that you want. And click Next. eg:

Primary IP address:192.168.1.1 Subnet Mask:255.255.255.0 Start IP Address:192.168.1.2 End IP Address: 192.168.1.254

7.Check the network information. Make sure the settings match the settings provided by ISP. Click Finish.