6.2Modem compatibility commands to MTs supporting GPRS

This subclause describes how existing AT commands, designed for use with a modem, may be used to control a GPRS MT. This is to provide backwards compatibility with existing communications soft- ware.

6.3 ATD *99# Request GPRS service

Execute command

ATD*99[*[<called_address>] [*[<L2P>][*[<cid>]]]]#

Reference

GSM 07.07

This command causes the MT to perform whatever actions are nec- essary to establish communication between the TE and the external PDN.

The V.25ter 'D' (Dial) command causes the MT to enter the V.25ter online data state and, with the TE, to start the specified layer 2 proto- col. No further commands may follow on the AT command line. GPRS attachment and PDP context activation procedures may take place prior to or during the PDP startup if they have not already been per- formed using the +CGATT (see Chapter 6.1.1) and +CGACT (see Chapter 6.1.2) commands. If the context to be used is already acti- vated, it will be deactivated first. This ensures that the right context parameters will be used (e.g. QoS changes since the last context ac- tivation or the called address specified by ATD).

Examples on how to use this command are provided in chapter 6.5.

Response

To confirm acceptance of the command to entering the V.25ter online data state:

CONNECT

When the layer 2 protocol has terminated, either as a result of an or- derly shut down of the PDP or an error, the MT enters V.25ter com- mand state and returns

NO CARRIER

Parameter

<called_address>

IP V4 address in the form w.x.y.z, see chapter “Using the GPRS dial command ATD“, pg. 169 which identifies the called party; if it is provided, the MT will automatically set up a virtual call to the specified address after the context has been activated. This parameter is currently not used and needs not be specified.

<L2P> layer 2 protocol to be used between the TE and MT PPP or layer2 for PPP protocol

<cid>: numeric parameter which specifies a particular PDP context definition (see +CGDCONT command). If no context is specified, an internal context 0 with default QoS (network subscribed) and APN from EEPROM (if there is one) is used.

1

2

Note: The +CGDCONT, +CGQREQ, etc. commands may be used prior to set values for cid, PDP type, APN, QoS etc..

Note

ATD is used as a standard V.25ter AT Command, too.

MC35_ATC_01_V04.00

Page 164 of 238

02.04.2002

Page 164
Image 164
Siemens MC35 manual Modem compatibility commands to MTs supporting Gprs, ATD *99# Request Gprs service, Calledaddress

MC35 specifications

The Siemens MC35 is a compact and versatile modem designed primarily for mobile communication, data transmission, and machine-to-machine (M2M) applications. Launched in the early 2000s, it quickly became popular due to its blend of performance, reliability, and ease of integration, making it a solid choice for developers and businesses.

One of the key features of the MC35 is its support for GSM and GPRS technologies. This allows it to connect seamlessly to various networks, enabling users to transmit data at speeds that were impressive for its time. The GPRS capability can offer data rates of up to 171.2 kbps, allowing for efficient data transfer even in areas with limited connectivity.

The MC35 is designed to support both SMS and voice functionalities, making it adaptable for a range of applications. This includes remote monitoring, telemetry, and alarm signaling. The ability to send and receive SMS messages is a significant advantage for applications that require immediate alerts and notifications, enhancing its utility in security systems and industrial automation.

Furthermore, the modem is equipped with a range of interfaces, including serial communication (RS232), which makes it compatible with various hardware devices. This facilitates easy integration into existing systems, whether for industrial machinery or consumer electronics. Additionally, it features a robust software development kit (SDK), which enables developers to create custom applications tailored to their specific requirements.

Power consumption is another notable characteristic of the Siemens MC35. It is engineered to be energy-efficient, which is especially important for battery-operated devices or systems that require a prolonged operation without frequent recharging or maintenance.

In terms of physical characteristics, the MC35 is compact and lightweight, allowing it to fit into various enclosure designs without occupying much space. Its durability ensures it can perform reliably in different environments, making it suitable for outdoor and industrial applications.

To summarize, the Siemens MC35 stands out as a reliable modem with a rich feature set that includes GSM and GPRS support, SMS and voice capabilities, easy integration through various interface options, and energy-efficient operation. Its adaptability makes it a valuable tool for a wide array of communication and data transmission tasks, solidifying its place in the evolution of mobile communications technology.