AT Command Set
MC35_ATC_01_V04.00 Page 38 of 238 02.04.2002
2.44 AT+ILRR Set TE-TA local rate reporting
Test command
AT+ILRR=?
Response
+ILRR: (list of supported <value>s) OK
Parameter
See write command
Read command
AT+ILRR?
Response
+ILRR: <value> OK
Parameter
See write command
Write command
AT+ILRR=
<value>
The write command specifies whether or not an intermediate result code sha ll in-
dicate the currently used local rate when an incoming or outgoing data call is es-
tablished. The message is transmitted from the DCE (= TA) to the DTE (=T E) be-
fore the final result code of the connection setup (e.g. CONNECT) appears.
Response
OK
Parameter
<value> 0 Disables reporting of local port rate
1 Enables reporting of local port rate
Intermediate result code
+ILLR:<rate>
Parameter
<rate> port rate setting in bit per second
0 (Autobauding, see Chapter 2.45.1)
300
600
1200
2400
4800
9600
19200
38400
57600
115200
Reference
V.25ter
Note
Example ATD030112233445
+ILRR: 57600
CONNECT 9600/RLP