B.1 Environmental Specifications
T
able B-1
Environmental
Specifications
Operating T
emperature 0_
to 60
_
C (32
_
to 140
_F)
Storage T
emperature –40_
to 70
_
C (–40
_
to 158
_F)
Relative Humidity 5% to 95% noncondensing
Pollution Degree
2, IEC 664, 664A
Vibration
Sinusoidal
IEC 68–2–6, T
est Fc;
0.15 mm, peak-to-peak, 10-57 Hz;
1.0 g 57-150 Hz
Random NAVMA
T P–9492 or IEC 68–2–34,
T
est Fdc with
0.04 g
@
/Hz, 80–350 Hz,
and 3 dB/octave rolloff, 80–20 Hz
and 350–2000 Hz at 10 min/axis
Impact Shock
IEC 68–2–27, T
est Ea;
Half Sine, 15 g, 1
1 ms
Electrostatic Discharge
2
IEC 801, Part 2, Level 4 (15 kV)
1
Electrical Noise Immunity IEC 801, Part 4, Level 3
Conducted2
MIL STD 461B, Part 4;
CS01, CS02, CS06
1
IEC 255–4, Appendix E
1
EEC 4517/79 Com(78) 766 Final, Part 4
IEEE 472, 2.5 kV
Radiated
IEC 801, Part 3, Level 3
MIL STD 461B, Part 4; RS01, RS02
Corrosion Protection
All parts are of corrosion resistant material
or are plated or painted as corrosion
protection.
Agency Approvals
ULr
Listed, CSA Certified
1The
unfilltered reset input may be susceptible to these types of EMI.
2
The module responds to noise signals at its count or inhibit inputs that are within its passband.