Configurable Digital Output Module

Communication-capable Circuit Breakers

WL Circuit Breaker

These events are available for the digital, configurable output module (part 1)

The configurable digital output module also has six outputs. Like the digital output module with the rotary switch, it is available with optocoupler and relay outputs.

Unlike the modules with the rotary switch, however, the outputs are assigned using a software tool rather than a selector switch. WinPM.Net, WL Config or the BDA can be used as configuration software. The outputs can be assigned the events in the table opposite using drop-down fields.

Status

Alarms

Circuit breaker closed

Circuit breaker open

Storage spring charged

Ready-to-close

Group warning

Group trip

MODBUS write protection active

MODBUS communication OK

Overload

Overload in N-conductor

Load shedding

Load restoring

The first three module outputs can be assigned up to six events. All of these events operate in parallel.

This triggers, for example, a type of group signal when the circuit breaker is either impending trip mode or a phase unbalance warning is present.

The last three outputs can only be assigned one of the events directly.

Configuration events include status signals, warnings, tripped indication, over/under setpoint status, waveform buffer triggers and the active parameter set.

The module outputs can be set remotely using communications.

Trips

Ground fault alarm

Overtemperature

ETU error

Phase unbalance - current

Long-time (L)

Short-time (S)

Instantaneous short-circuit (I)

Ground fault (G)

Overload in neutral conductor

Phase unbalance - current

Phase unbalance - voltage

Under frequency

Over frequency

Undervoltage

Overvoltage

Active power in normal direction

Active power in reverse direction

Total harmonic distortion - current

Total harmonic distortion - voltage

Reversal of phase rotation direction

MODBUS bit 1

MODBUS bit 2

MODBUS bit 3

MODBUS bit 4

MODBUS output bits

MODBUS bit 5

MODBUS bit 6

Parameter set A active

Parameter set B active

Table 2-17The events in this table (part 1) and the following table (part 2) are available on the CubicleBUS. These can be output via the configurable digital output module.

2/26

WL MODBUS Communication and Electronic Accessories • January 2005

Page 37
Image 37
Siemens UL 489, UL1066 specifications Configurable Digital Output Module

UL 489, UL1066 specifications

Siemens UL1066 and UL489 are essential components in the landscape of electrical equipment, specifically in circuit protection and control. These standards ensure reliability, safety, and efficiency in various applications, including industrial, commercial, and residential settings.

The Siemens UL1066 is primarily focused on disconnect switches. These devices are designed to isolate electrical circuits, ensuring the safety of both personnel and equipment during maintenance or in case of faults. One of the key features of UL1066 disconnect switches is their high breaking capacity, enabling them to handle significant fault currents without failure. This characteristic is crucial in protecting downstream equipment from damage caused by short circuits. The UL1066 switches are also known for their robust construction, often featuring a metal enclosure that enhances durability and environmental resistance. Additionally, these switches can be operated manually or remotely, offering flexibility in operation and control.

On the other hand, Siemens UL489 circuit breakers provide comprehensive protection against overcurrents and short circuits. These devices not only interrupt fault currents but also protect connected devices from damage due to overload situations. Key features of UL489 circuit breakers include adjustable trip settings, which allow users to customize the response to overcurrent conditions based on specific application requirements. This adaptability makes them suitable for a wide range of environments, from large industrial plants to smaller commercial buildings.

Both UL1066 and UL489 products are constructed with advanced technologies, such as thermal-magnetic or electronic trip mechanisms in UL489 devices, ensuring precise and timely interruption of fault currents. These technologies promote energy efficiency and stability within electrical systems. In addition, many of these devices are equipped with indication features, providing clear visual status cues for quick assessment in emergency situations.

In terms of characteristics, both UL1066 and UL489 devices adhere to rigorous testing and certification processes to meet UL standards. This compliance assures users of their performance and reliability. Furthermore, the devices are designed to accommodate a wide range of operating temperatures and environmental conditions, making them versatile choices for various applications.

In summary, Siemens UL1066 and UL489 devices are paramount in ensuring safety and efficiency in electrical circuits. Their advanced features and robust construction make them indispensable in protecting both personnel and equipment in an array of industrial and commercial applications.