8.SPECIFICATIONS (Continued)
Model | |||||
Gas | NO2 | HCL | HCN | NH | HF |
Sensor Type | E.C. | E.C. | E.C. | 3 | E.C. |
E.C. | |||||
Units | ppm | ppm | ppm | ppm | ppm |
Range | |||||
Resolution | 0.2 | 0.5 | 0.1 | 0.1 | 0.5 |
Response Time | 35 sec. | 150 sec | 70 sec. | 45 sec. | 30 sec. |
to 90% of signal |
|
|
|
|
|
Sensor Life 2 | 2 yrs | 2 yrs | 2 yrs | N/A | N/A |
Operating Range |
|
|
|
|
|
Temperature | 14 to 122oF | 14 to 122oF | 14 to 122oF 14 to 113oF | 14 to 113oF | |
| |||||
Relative Humidity | |||||
Pressure | 10% | 10% | 10% | 10% | 10% |
Electrical Data |
|
|
|
|
|
Input Voltage DC |
|
| |||
|
| ||||
|
|
| 0 mA |
| |
Construction |
|
|
|
|
|
Dimensions |
| H: 7.6", D: 4.6", W: 4.2" (19.3 x 11.7 x 10.7 cm) | |||
Weight (Module) |
|
|
| 5.0 lb. (2.2 kg) | |
Mounting |
|
|
| 3/4" NPT |
|
Housing |
|
| Explosion proof |
(NEMA 7) / NEMA 4X Enclosure (Div. I, Class 1, Groups B, C, D)
Notes: 2. Sensor life is for use at standard temperature and pressure with occasional exposure to the gas of interest 3. Diffusion via membrane. Dimensions are H: 10.2", D: 6.0", W: 6.0" (25.9 x 15.2x 15.2 cm)
Model 4105 Gas Sensor Module (12/02) | Page: 11 |