8.SPECIFICATIONS (Continued)

Model

4105-12

4105-21

4105-22 4105-253

4105-263

Gas

NO2

HCL

HCN

NH

HF

Sensor Type

E.C.

E.C.

E.C.

3

E.C.

E.C.

Units

ppm

ppm

ppm

ppm

ppm

Range

0-20

0-20

0-20

0-50

0-10

Resolution

0.2

0.5

0.1

0.1

0.5

Response Time

35 sec.

150 sec

70 sec.

45 sec.

30 sec.

to 90% of signal

 

 

 

 

 

Sensor Life 2

2 yrs

2 yrs

2 yrs

N/A

N/A

Operating Range

 

 

 

 

 

Temperature

14 to 122oF

14 to 122oF

14 to 122oF 14 to 113oF

14 to 113oF

 

-10 to 50oC

-10 to 50oC

-10 to 50oC

-10 to 45oC

-10 to 45oC

Relative Humidity

15-90%

15-90%

15-90%

20-90%

20-90%

Pressure

10%

10%

10%

10%

10%

Electrical Data

 

 

 

 

 

Input Voltage DC

 

 

19-30 VDC at less than 100 mA

Output-Normal

 

 

4-20 mA DC linear

Output-Trouble

 

 

 

0 mA

 

Construction

 

 

 

 

 

Dimensions

 

H: 7.6", D: 4.6", W: 4.2" (19.3 x 11.7 x 10.7 cm)

Weight (Module)

 

 

 

5.0 lb. (2.2 kg)

Mounting

 

 

 

3/4" NPT

 

Housing

 

 

Explosion proof

(NEMA 7) / NEMA 4X Enclosure (Div. I, Class 1, Groups B, C, D)

Notes: 2. Sensor life is for use at standard temperature and pressure with occasional exposure to the gas of interest 3. Diffusion via membrane. Dimensions are H: 10.2", D: 6.0", W: 6.0" (25.9 x 15.2x 15.2 cm)