Sigma AS-H50Y Control Panel Function - Error Display, PLEASE ALSO SEE PAGE 15 - FILTRATION & FAQ

Models: AS-H40Y AS-H60Y AS-H50Y

1 20
Download 20 pages 17.99 Kb
Page 15
Image 15
CONTROL PANEL FUNCTION - ERROR DISPLAY 1-4

CONTROL PANEL FUNCTION - ERROR DISPLAY 1-4

IF THE HEATER STOPS WORKING ONE OF THE FOUR ERRORS WILL BE DISPLAYED THE FAILURE LIGHT WILL BE ON AND THE RELEVANT CODE WILL START TO FLASH

E1: the water temperature sensor is not working correctly.

E2 : the tube sensor is not working correctly. Please contact your dealer.

E3 : Pool filtration is running but water flow is not sensed. ‘Flow Switch’ may not be working properly or there is a lack of water flow. Backwash filter and check suction lines (Skimmer(s) & Main Drain(s) for obstruction.

PLEASE ALSO SEE PAGE 15 - FILTRATION & FAQ

E4 : Indicates high water/refrigerant pressure. High limit pressure switch has activated and turned off power supply.

14

Page 15
Image 15
Sigma AS-H50Y, AS-H60Y, AS-H40Y Control Panel Function - Error Display, PLEASE ALSO SEE PAGE 15 - FILTRATION & FAQ