INSTALLATION AND SITING

Prior to installing your heat pump:-

All heat pumps are factory assembled and tested prior to delivery. Please check for any external damage especially to the evaporator fins, please diagram below. Do not be concerned about minor damage or indentations to the fins (especially where the fan unit is mounted) as it will not affect performance. If severe damage has occurred please contact your supplier immediately and do not attempt to install heater unit.

IF HEAT PUMP HAS BEEN PLACED ON IT’S SIDE IN TRANSIT THEN HEATER MUST BE LEFT

IN AN UPRIGHT POSITION FOR A MINIMUM PERIOD OF 24HRS PRIOR TO OPERATION (failing the above may cause damage to the heat pump and invalidate your warranty).

Siting

As the air flow is discharged from the top of the heat pump all units are designed to be installed outside. If unit is to be installed inside the filtration/plant room adequate ducting and ventilation must be installed. Please contact your dealer for advice.

Heater unit must be installed using plastic anti vibration pads (provided) on a solid LEVEL foundation i.e. concrete base or paving slabs. Using the plastic pads reduces vibration noise and prevents corrosion to the base of the heat pump. DO NOT PLACE ONTO SOFT GROUND I.E. GRASS. Please Note: the heat pump collects condensation from the evaporator fins and will continually discharge small amounts of condensate (water) out of the base of the unit via a drain tube. Therefore, it is recommended that the drain tube is directed to an area with adequate drainage.

Make sure that heat pump remains free of any obstructions, foliage etc. A minimum clearance is required around heater unit, please see drawing below. Make sure that easy access can be gained to service panel and plumbing connections. Do not obstruct access panel with plumbing pipework.

Multiple connections- install heat pumps 500mm apart and independently protect each unit by 20amp MCB - see also page 8, Drw.4 for plumbing detail. Make sure that heat pump grilles are not blocked by loose debris such as leaves, grass cuttings, garden

furniture etc. 3500mmMin.

Min.

1000mm

Evaporator Fins x 3 sides (protected by a wire mesh grille)

.800mm Min

2.5mm Cable

Power Supply

(prefitted)

.1000mm

Min

Min. 500mm

Drain Tube

(optional)

4

Page 5
Image 5
Sigma AS-H40Y, AS-H50Y, AS-H60Y installation manual Installation and Siting, Prior to installing your heat pump

AS-H40Y, AS-H60Y, AS-H50Y specifications

The Sigma AS-H50Y, AS-H40Y, and AS-H60Y are high-performance amplifiers designed for audio professionals and enthusiasts who demand exceptional sound quality and reliability. Each model brings unique features and technologies to the table, catering to a variety of audio applications ranging from live sound reinforcement to studio monitoring.

The AS-H50Y is a compact yet powerful amplifier that delivers a robust 250 watts of continuous power per channel, making it ideal for smaller venues or portable sound systems. Its lightweight design enhances portability, while advanced thermal management ensures optimal performance even during extended use. The AS-H50Y incorporates a Class D amplifier architecture, providing high efficiency and low distortion. Its built-in limiters protect both the amplifier and connected speakers from damage, guaranteeing a long lifespan and reliable operation.

Moving to the AS-H40Y, this model is engineered for incredible versatility, offering an impressive power rating of 400 watts per channel. One of its standout features is the integrated digital signal processing (DSP), which allows users to fine-tune audio output to their specific needs. The DSP functionality includes multi-band EQ, time alignment, and various presets tailored for different environments. Additionally, the AS-H40Y boasts multiple input and output options, making it compatible with a wide range of audio sources, from microphones to instruments.

The AS-H60Y takes things up a notch with an outstanding 600 watts per channel output, making it suitable for larger venues and professional applications. This amplifier also incorporates advanced networking capabilities, allowing for remote control and monitoring via a dedicated app. This feature enables users to adjust settings on the fly, ensuring optimal sound quality during performances. The AS-H60Y uses advanced heat dissipation technology, ensuring that the unit remains cool and operates efficiently even under high load conditions.

All three models share critical characteristics, including rugged construction designed for reliability, high-quality components for superior audio fidelity, and flexible connectivity options. With their respective power outputs and features, the Sigma AS-H50Y, AS-H40Y, and AS-H60Y cater to a wide range of audio needs, making them excellent choices for those seeking outstanding performance in various settings. Whether for live sound, installations, or studio work, these amplifiers provide the power and flexibility essential for modern audio challenges.