CONTROL PANEL FUNCTIONS
When the SET button is pressed for the fourth time, the display panel will display:-
F4 : Operation Mode.
F4 C : Cooling Mode.
F4 H : Heating Mode
New
economy
Setting!
When the SET button is pressed for the fifth time, the display panel will display:-
F5 : The defrosting temperature of the evaporator pipe. The recommended temperature setting for the UK should be set to 0°C. To adjust setting YOU MUST PRESS THE ON/OFF BUTTON FIRST. The temperature can be adjusted using the UP and DOWN buttons between
When the SET button is pressed for the sixth time, the display panel will display:-
F6 : EC (Economy) OR ST (Standard) This function is designed for saving energy.
EC: Heat pump will stop working at an ambient temperature of 5°C and will automatically restart when the ambient temperature rises above 10°C
Example. When the heat pump is set in Economy mode, the unit will stop working during the night (when temperature drops below 5°C) and will restart automatically when the temperature rises throughout the day.
ST: (may be shown as 57) The heat pump will work continuously until the desired temperatures are reached.
To adjust setting YOU MUST PRESS THE ON/OFF BUTTON FIRST.
F7 IS ONLY DISPLAYED IF AN ELECTRIC
When the SET button is pressed for the seventh time, the display panel will display:- This function is used only in conjunction with a
F7 : ON/OFF Function. 0= turns off heater. 1= turns on electrical heater.
12