3.7Replacement of Fuse

3. MAINTENANCE, TROUBLESHOOTING

3.7Replacement of Fuse

The 3 A fuse on the POWER Board inside the processor unit protects the equipment from overcurrent and reverse polarity of the power supply. If the fuse blows, have a qualified technician check the fuse.

3.8Error Messages WARNING

Use the proper fuse.

Use of a wrong fuse can result in damage to the equipment or cause fire.

3.8Error Messages

The alarm sounds for equipment error and is accompanied by a flashing exclamation mark (Message display). Press any key to silence the alarm. The exclamation mark remains on the screen until the cause for error is eliminated. Find the cause for the alarm(s) as follows:

1.Press the [MENU] key to open the menu.

2.Choose MESSAGES and then press the [ENT] key.

Error Message MESSAGESMeaning

(Continued on next page)GPS DATA ERROR!

Message display

3.Press the [DISP] key to close the menu. Error messages

Error Message

Meaning

Remedy

ABORTING!

GPS heading error continues for

Check for obstruction.

 

one minute. For example, satellite

 

 

cannot be acquired because of

 

 

unfavorable environment.

 

ABORTING CALC!

GPS signal lost for one minute.

Press any key to try to restore

 

 

normal operation.

BACKUP ERROR!(DISP)

Corrupted backup data found in

Default settings are

 

display unit at power on.

automatically restored.

BACKUP

Corrupted backup data found at

Default settings are

ERROR!(PRCSSR)

processor unit at power on.

automatically restored.

(Continued on next page)