APPENDIX

 

 

 

 

 

 

Port

Terminal Name

I/O

Signal

Remarks

 

Label

 

 

 

 

 

DATA

WAGO

O

Heading

AD-10 only

 

OUT6

231-304/026-000

 

 

AD-10 output interval: 25ms

 

LOG/

WAGO

O

LOG

200 pulse/nm or 400 pulse/nm (software),

 

ALARM

231-306/026-000

 

Signal

0.5A max.

 

 

 

 

HDG

Heading alarm, 0.5A max, normal close

 

 

 

 

alarm

 

 

DATA IN

WAGO

O

Heading

Heading data in either AD-10 or

 

 

231-305/026-000

 

 

IEC61162(NMEA0183) format (4800, 9600,

 

 

 

 

 

19200, 38400bps) is automatically received.

 

 

 

 

 

Priority of IEC61162(NMEA0183) sentence is

 

 

 

 

 

HDT>HDG>HDM.

 

 

 

 

 

The signal is selected through the menu

 

 

 

 

 

during the period of internal heading sensor

 

 

 

 

 

failure.

 

 

 

 

 

VBW/VHW may be input from a current

 

 

 

 

 

indicator.

 

AP-9

Page 69
Image 69