1.7Connection of External Equipment

1. INSTALLATION

1.7Connection of External Equipment

1.7.1General wiring

All external equipment are terminated on the MAIN Board inside the processor unit. Turn off the power and unfasten four screws to remove the cover. Connect wiring from external equipment referring to the interconnection diagram. Use the opener supplied to open terminal blocks, referring to the instructions below.

Recommended Cables*:

Power cable:DPYC-1.5

IEC 61162 equipment: TTYCS-1

AD-10 equipment: TTYCS-1Q

* Or equivalent

How to insert cores in terminal blocks

Opener

1. Insert opener.

2. Press opener.

3. Insert core.

4. Release opener.

Power Cable

From top: Analog Roll, Analog Pitch, 2-pole)

LOG/ALARM (Contact signal, 6-pole)

DATA IN (AD-10/IEC 61162-1/2, 5-pole)

BEACON EXT (RTCM SC-104, 3-pole)

DATA OUT6 (AD-10, 4-pole)

DATA OUT1-DATA OUT5 (AD-10/IEC 61162-1/2, 4-pole)

Processor unit, cover opened

1-17