1.7.2Fabrication of cables

1. INSTALLATION

1.7.2Fabrication of cables

Cable

Sectional view, fabrication

 

Power cable

 

50

50

DPCY-1.5

 

Sheath

Armor

(or equivalent)

Armor

 

 

 

Sheath

φ

= 11.7 mm

 

 

Cut the sheath.

 

15

 

 

Conductor

6

 

 

 

 

 

S = 1.5 mm 2

 

 

 

 

φ = 1.56 mm

 

 

 

 

SECTIONAL VIEW

Crimp-on lug

Vinyl tape

Lay in clamp

 

 

FV1.25-5

 

where paint

 

 

FABRICATION

was removed.

Cable for IEC 61162

Armor

80

 

50

format equipment (JIS

 

 

 

 

 

cable TTYCS-1 or

Sheath

Shield

 

Remove paint

equivalent)

 

 

 

by 50 mm.

Shield

 

Cut vinyl sheath.

φ

 

= 10.1 mm Conductor

 

 

 

Cable for AD-10

S = 0.75 mm2

 

 

 

format equipment

φ = 1.11 mm

 

 

 

SECTIONAL VIEW (TTYCS-1)

 

shield onto cable.

((JIS cable TTYCS-1Q

 

 

 

 

Expose core and fold back

or equivalent)

 

 

Vinyl tape

 

 

 

Armor

15 45

6

Sheath

φ

Shield

Lay in clamp

= 11.3 mm

where paint

 

Conductor

was removed.

 

S = 0.75 mm2

 

φ= 1.11 mm

SECTIONAL VIEW (TTYCS-1Q)

FABRICATION

 

Note 1: Attach labels (supplied) to cables to differentiate between them.

Note 2: A plastic sheet is placed across the cable glands of the processor unit to keep out foreign material. Cut out holes in the plastic where cables are to be lead in.