Furuno SC-110 manual Diagnostic test3, TEST3 menu, ALARM options, TEST1, TEST2 TEST3, Test Start?

Models: SC-110

1 93
Download 93 pages 16.89 Kb
Page 56
Image 56
Diagnostic test3

3. MAINTENANCE, TROUBLESHOOTING

Diagnostic test3

This test checks the buzzer signal/contact for proper operation.

1.Press the [MENU] key to open the menu.

2.Choose SYS SETUP and then press the [ENT] key.

3.Choose TEST? and then press the [ENT] key.

TEST1

TEST2

TEST3

Test menu options

4. Choose TEST3 and then press the [ENT] key.

TEST START?

(STOP: PWR OFF)

ARE YOU SURE?

YES

NO

Test start prompt

5. Press to choose YES and then press the [ENT] key.

TEST3

ALARM: OFF

TEST3 menu

6. Press the [ENT] key.

OFF

ON

ALARM options

7. Choose OFF or ON as appropriate and then press the [ENT] key.

OFF: Buzzer sound goes off, alarm contact signal is closed.

ON: The buzzer sounds and the alarm contact is open.

8. To quit the test, turn off the processor unit.