Furuno SC-110 manual Digital Interface, Output sentences of channel, Transmission interval, AP-2

Models: SC-110

1 93
Download 93 pages 16.89 Kb
Page 62
Image 62
2. Digital Interface

APPENDIX

2. Digital Interface

Output sentences of channel 1

DATA OUT1-5: HDT, HDM, ROT, Patt, Phve, VTG, GGA, GLL, GNS, ZDA, VHW, VBW, VDR

DATA OUT 6: AD-10

Transmission interval

HDT, HDM, ROT, Patt, Phve: 100 ms

VTG, GGA, GLL, GNS, ZDA, VHW, VBW, VDR: 1 s

For details see page 2-12.

Load requirement as listener

Isolation: Optocoupler

Input Impedance: 220 ohms

Max. Voltage: ±15V

Threshold: 4 mA

Data transmission

Data is transmitted in serial asynchronous form in accordance with the standard referenced in 2.1 of IEC 61162-1. The first bit is a start bit and is followed by data bits, least-significant-bit as illustrated below.

The following parameters are used:

Baud rate: 4800

Data bits: 8 (D7 = 0), parity none

Stop bits: 1

 

 

 

 

D0

D1

D2

D3

D4

D5

D6

D7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start

 

 

 

 

 

 

 

 

 

Stop

 

 

 

 

 

 

Data bits

 

 

 

 

 

 

 

bit

 

 

 

 

 

 

bit

 

 

AP-2

Page 62
Image 62
Furuno SC-110 Digital Interface, Output sentences of channel, Transmission interval, Load requirement as listener, AP-2