New Shallow Well Installation

5

WELL POINT INSTALLATION (Figure 5)

1.Install the control valve and pressure gauge in the pump body (see Figure 1).

2.Install ejector kit FP4875 or 29650 (kits are sold sep- arately). Follow the instructions provided with the kit. Align the venturi with the top hole on the front of the pump (see Figure 4).

3.Drive the well, using “drive couplings” and a “drive cap”. “Drive fittings” are threaded all the way through and allow the pipe ends to butt against each other so that the driving force of the maul is carried by the pipe and not by the threads. The ordinary fittings found in hardware stores are not threaded all the way through the fitting and can collapse under impact. “Drive fit- tings” are also smoother than standard plumbing fit- tings, making ground penetration easier.

4.Mount the pump as close to the well as possible.

5.Use the fewest possible fittings (especially elbows) when connecting the pipe from the well point to the pump suction port. The suction pipe should be at least as large as the suction port on the pump (include a check valve – see Figure 5). Support the pipe so that there are no dips or sags in the pipe, so it doesn’t strain the pump body, and so that it slopes slightly upward from the well to the pump (high spots can cause air pockets which can air lock the pump). Seal the suction pipe joints with teflon tape or pipe joint compound approved for use on PVC. Joints must be air- and water-

tight. If the suction pipe can suck air, the pump cannot pull water from the well. If one well point does not supply enough water, consider connecting two or three well points to one suction pipe.

You have just completed the suction piping for your new shallow well jet pump. Please go to Page 8 for discharge pipe and tank connections

CASED WELL INSTALLATION, 2" OR LARGER CASING (Figure 6)

1.Install the control valve and pressure gauge in the pump body (see Figure 1).

2.Install ejector kit FP4875 or 29650 (kits are sold sep- arately). Follow the instructions provided with the kit. Align the venturi with the top hole on the front of the pump (see Figure 4).

3.Mount the pump as close to the well as possible.

4.Assemble the foot valve, strainer, and well pipe (see Figure 6). Make sure that the foot valve works freely.

5.Lower the pipe into the well until the strainer is five feet above the bottom of the well. It should also be at least 10 feet below the well’s water level while the pump is running in order to prevent the pump from sucking air. Install a sanitary well seal.

6.Install a priming tee, priming plug, and suction pipe to the pump (see Figure 6). Connect the pipe from the well to the pump suction port, using the fewest

To Household

 

Water System

 

Pressure Gauge

 

and Priming Port

Relief Valve

 

P

Suction Pipe

 

 

From Well

To Household

 

Water System

 

Pressure Gauge

 

and Priming Port

Relief Valve

P

Suction Pipe

 

 

From Well

Built-in

 

Check Valve

 

Built-in

Check

Valve

222 0395

Not

to

Scale

Priming

Tee and

Plug

Check

Valve

Drive

Coupling

Drive

Point

Priming

Tee and

Plug

Sanitary

Well Seal

256 0395

Well

Casing

Not

 

 

to

At least

Foot

Scale

Valve

10'

 

5-10'

Strainer

Figure 5: Driven Point Installation

Figure 6: Cased Well Installation

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Page 5
Image 5
Simer Pumps 3305P, 3310P, 3307P New Shallow Well Installation, Cased Well INSTALLATION, 2 or Larger Casing Figure