SkyLink SC-100 INSTALLING THE DOOR/WINDOW SENSOR WT-433, INSTALLING THE MOTION SENSOR PS-434A

Models: SC-100

1 51
Download 51 pages 48.89 Kb
Page 6
Image 6
INSTALLING THE DOOR/WINDOW SENSOR (WT-433)

INSTALLATION

4.Attach the unit to the wall. If hanging the unit, insert two screws using the template provided. If screwing the back directly to the wall, take the back plate right off by prying apart one hinge. Use as much force as needed. The plastic hinge will not break.

5. Using the template, attach the backplate on to the wall with 4 screws.

6. Mount the Control Panel on the backplate. Insert

one hinge into the hole, then twist the other hinge

INSTALLATION

2.Position the magnetic switch connected to the transmitter on the door/window frame.

3.Position the magnet on the door beside the magnetic switch. They should be no more than 1 cm (3/8 inch) apart. When the door/ window is closed, the magnets are in contact. When the door/window is opened, contact is broken and the transmitter sends a signal to the Control Panel to activate the chime or alarm.

into position.

7. Firmly close the case.

8. Plug the AC adapter into a power outlet. The red

AC PWR light will be on.

INSTALLING THE DOOR/WINDOW SENSOR (WT-433)

It is recommended to install one sensor on your front door and the other on your back door.

Each contact sensor has 4 parts:

Transmitter Magnetic Switch

Magnet

Spacers

INSTALLING THE MOTION SENSOR (PS-434A)

Insert a 9V alkaline battery to the motion sensor. The sensor requires a warm up time of approx. 45 seconds before it can function properly. After powering up the sensor, face it to the wall where no motion will be detected. After 45 seconds, the sensor is ready.

SENSOR SENSITIVITY

The sensitivity of the motion sensor is adjust- able. Change the setting by placing the connector on either the ”High” or “Low” position. When the sensitivity is set to “Low”, more movement is required to trigger the sensor. It is recommended to set the sensitivity to “Low” and perform a “Walk Test” (Described in later Section). If the walk test result is satisfied, the sensitivity does not require to be adjusted further. If the walk test result shows the sensitivity is too low, then you can change the sensitivity setting to “High”. Please perform the walk test after changing the sensitivity setting.

Insert 9V alkaline battery to the sensor

Sensitivity Connectors on Motion Sensor

1.Position the transmitter be- side the door/window frame on the wall using either two sided tape or screws. If you are using screws, first pry off the back plate with a small screwdriver and

screw the back plate into posi- tion using the template. Then click the transmitter on to the back plate now mounted on the wall.

MOUNTING Note: High=1, Low=2, Default is 1

A ball-head joint is necessary to mount the sensor at a desire location. A height of 5-6 ft is recommended, depending on your application. Once a location is selected, mount the ball-head joint to this location by screws provided, (see diagram 1). Once the ball-head joint is mounted to the wall, slide the back of the sensor into the ball- head joint (see diagram 2). The mounting angle can be adjusted. Please refer to Section “Walk Test” to determine the best mounting angle.

Diagram 1

Diagram 2

7

8

Page 6
Image 6
SkyLink SC-100 INSTALLING THE DOOR/WINDOW SENSOR WT-433, INSTALLING THE MOTION SENSOR PS-434A, Sensor Sensitivity, Magnet