Instructions for the installer

8.2Electrical connection

Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing.

Do not remove this plate for any reason.

The plug at the end of the power cable and the wall socket must be compatible and in compliance with current legislation on electrical systems. Make sure that the supply line is suitably earthed.

Fit power line with an omnipolar circuit breaker with a contact opening gap equal to or greater than 3 mm in an easily accessible position close to the hob.

Avoid the use of adapters and shunts.

If the power cable needs to be replaced, the wire section of the new cable should not be less than 0.75

mm2 (3 x 0.75 cable), with the exception of the induction hob where the section should be no less than

1.5mm2 (3 x 1.5 cable), bearing in mind that the end piece to be connected to the appliance must have an earth wire (yellow-green) that is at least 20 mm longer.

Only use a H05V2V2-F or similar resistance cable to the maximum temperature of 90°C. Its replacement must be carried out be a specialised technician who must carry out the network connection following the diagram below.

L = brown N = blue

= yellow-green

The manufacturer declines all responsibility for damage to persons or things caused by the non-observance of the above indications or as a result of tampering with any part of the appliance.

63

Page 27
Image 27
Smeg A31G7IXIA manual Electrical connection, Do not remove this plate for any reason