Smeg CS150SA manual Description Of Controls, Instructions for the Installer

Models: CS150SA

1 43
Download 43 pages 39.54 Kb
Page 10
Image 10
4. DESCRIPTION OF CONTROLS

Instructions for the Installer

4. DESCRIPTION OF CONTROLS

After changing the nozzles, put the pan stands, the burner caps and flame diffuser rings back in place.

After adjusting for use of a gas other than the gas used for testing the appliance, replace the gas setting label on the appliance with the label for the new gas. The label is supplied in the bag with the nozzles.

4.1Adjusting the minimum setting for natural gas

Light the burner and turn it to the minimum setting

4.1Adjusting the minimum setting for natural gas Remove the gas tap knob and adjust the regulator screw inside or beside the tap rod (depending on the model) until an even minimum flame is obtained. Put the knob back in place and check the stability of the burner flame (the flame must not go out when the knob is turned quickly from the maximum to the

4.2Adjusting the minimum for bottled gas

To adjust the minimum level when using bottled gas, the adjuster screw inside or beside the tap rod must be turned fully clockwise (depending on the models).

The diameters of the bypasses for each individual burner are stated in point "3.2 Burner and Nozzle Data Tables".