The cleaning cycle must always be preset.

Instructions for the User

The cleaning cycle can be programmed to start at a preset time. Turn the knob A anticlockwise to set the Pyrolysis duration in the window B. PULL the knob A and turn it anticlockwise until the arrow C is in line with the cooking start time required.

The cleaning cycle must always be preset.

13.6.5 How the automatic cleaning cycle works (for models with electronic analogue clock)

The table below shows an example of operation of the automatic cleaning cycle.

One minute after the start of the pyrolysis cycle, an interlock device which prevents opening of the door is tripped and number 12 on the timer starts to flash.

The door interlock is only released later, when the temperature inside the oven drops back below 300°C, and number 12 on the timer stops flashing.

13.6.6 Setting the cleaning cycle with electronic analogue clock

FUNCTION SELECTOR KNOB

CLEANING CYCLE DURATION

Turn the function selector knob to the FUNCTION SELECTOR KNOB symol. The segments relating to the 90 minutes after the current time will illuminate on the display. Press the Manual background keywithin 1/2 seconds to increase the duration of this operation up to a maximum of three hours. 6/7 seconds after the knob has been turned to the Manual background symbol or the pyrolysis duration has been set, the oven will start the cycle. The internal and external segments on the display will flash in alternation, and finally they will go out, to be replaced by constant display of the current time. The segments will continue to flash until the end of the pyrolysis.

The start of the pyrolysis cycle can be programmed within the next 12 hours. After setting the pyrolysis duration, press the Manual background key and set the pyrolysys start time by pressing the Manual background / Manual background keys. The internal segments will remain on and the external ones will flash until the current time is the same as the cycle start time. The process will now start and the segments will start to flash as already described.