Instructions for the installer
4. FINAL OPERATIONS
After replacing the nozzles, reposition the
4.1Adjustment of the hob burner minimum level for natural gas
Light the burner and take it to the minimum . Remove the gas tap knob and turn the adjustment screw inside of the tap shaft (depending on the model) until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.
4.2Adjustment of the hob burner minimum level for LPG
(propane)
To regulate the minimum for LPG (propane), completely tighten (clockwise) the screw inside or next to the gas tap pin (depending on the model).
4.3Arrangement of the burners on the hob
Burners
1 | Auxiliary |
2 | Semi rapid |
4Wok
12