16.EXTRAORDINARY MAINTENANCE

Instructions for the User

16.EXTRAORDINARY MAINTENANCE

The oven may require extraordinary maintenance or replacement of parts subject to wear such as seals, bulbs, and so on. The following instructions describe how to carry out these minor maintenance operations.

Before performing any operations requiring access to powered parts, switch off the power supply to the appliance.

16.1 Changing the light bulb

Remove the protective cover A by unscrewing it clockwise; replace the bulb B with another of the same type (25 W). Re-fit the bulb protector A.

Use only oven bulbs (T 300°C).

16.2 Removing the door (auxiliary and static oven)

Open the door completely and insert the pins (supplied) into the holes from the inside. Close the door to an angle of about 45° and lift it off. To reassemble, fit the hinges into their grooves, then lower the door into place and extract the pins.