Instructions for the installer
5.2 Burner and nozzle characteristics table
| Rated heating |
|
|
|
|
|
|
| |
Burner | capacity (kW) |
| LIQUID GAS – G30/G31 28/37 mbar |
| |||||
|
|
|
|
|
|
|
| Capacity |
|
|
|
| Nozzle | Reduced |
| Capacity | |||
|
|
| diameter | 1/100 | capacity |
| g/h G30 | g/h G31 | |
|
|
| 1/100 mm | mm | (W) |
|
|
| |
|
|
|
|
|
|
|
| 73 |
|
Auxiliary | 1.0 |
| 50 | 30 | 400 |
|
| 71 | |
Semi rapid | 1.8 |
| 65 | 33 | 500 |
|
| 127 | 125 |
Rapid | 3.0 |
| 85 | 45 | 800 |
|
| 218 | 214 |
4.0 |
| 100 | 65 | 1600 |
|
| 291 | 286 | |
|
|
|
|
|
|
|
|
|
|
Burner | Rated heating |
| NATURAL GAS – G20/G25 20/25 mbar |
| |||||
capacity (kW) |
|
| |||||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
| Nozzle diameter |
|
|
| Reduced capacity | ||
|
|
|
| 1/100 mm |
|
|
| (W) |
|
|
|
|
|
|
|
|
|
| |
Auxiliary | 1.0 |
|
| 72 (X) |
|
| 400 |
| |
Semi rapid | 1.8 |
|
| 97 (Z) |
|
| 500 |
| |
Rapid | 3.0 |
|
| 115 (Y) |
|
| 800 |
| |
4.0 |
|
| 135 (K) |
|
| 1600 |
| ||
| 5.3 Arrangement of the burners on the cooking hob |
|
|
| |||||
|
|
|
|
|
|
| BURNERS | min. and max. | |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| Ø (in cm) |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 1. Auxiliary | 12 - 14 | |
|
|
|
|
|
|
| 2. Semi rapid | 16 - 24 | |
|
|
|
|
|
|
| 3. Rapid | 18 - 26 | |
|
|
|
|
|
|
| 4. | 18 - 28 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
11