6.FINAL OPERATIONS

Instructions for the installer

6.FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the pan stands.

Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the appliance with the one corresponding to the new gas. This label is inside the packing containing the nozzles.

6.1 Regulation of the hob burner minimum level for natural gas

Light the burner and turn it to the minimum position 6.3 Positioning and levelling the appliance. Extract the gas tap knob and turn the adjustment screw at the side of the tap rod until the correct minimum flame is achieved.

Refit the knob and verify that the burner flame is stable (turning the knob rapidly from the maximum to the minimum position the flame must not go out). Repeat the operation on all the gas taps.

For models with valves, keep the knob at minimum level for a few seconds to keep the flame lit and to activate the safety device.

6.2 Regulation of the hob burner minimum level for LPG

In order to adjust the minimum with liquid gas, the screw at the side of the tap rod must be tightened clockwise all the way.

The bypass diameters for each individual burner are shown in paragraph “5.2 Burner and nozzle characteristics table”. When the adjustment is completed, restore the sealing of the by-passes with paint or other material.

6.3 Positioning and levelling the appliance

After making the electrical and gas connections, level the appliance on the floor by means of its four adjustable feet. For good cooking results, the appliance must be properly levelled.