Fan Speed Control with the EMC2102 Device

5.3.6Register Change Summary

Table 5.2, "Register Change Summary for Experiment 3" lists all register value changes from the default cmf load to accomplish the tests.

Table 5.2 Register Change Summary for Experiment 3

REGISTER

 

DEFAULT

NEW

 

NAME

ADDRESS

VALUE

VALUE

COMMENT

 

 

 

 

 

FAN Spin Up

53h

01h

03h

SPINUP_TIME of 2.0 sec

Configuration

 

(00000001b)

 

 

 

05h

Change the LEVEL from 60% to 75%

 

 

 

 

 

 

 

 

SMSC EMC2102

USER MANUAL

Revision 0.2 (09-17-07)

19