5.5.4Register Change SummaryTable 5.4, "Register Change Summary for Experiment 7" lists all register value changes from the default cmf load to accomplish the tests.
Table 5.4 Register Change Summary for Experiment 7REGISTER |
| DEFAULT | NEW |
|
NAME | ADDRESS | VALUE | VALUE | COMMENT |
|
|
|
|
|
Fan | 52Bh | CBh | 4Bh | Disable RPM based fan control algorithm |
Configuration |
|
|
|
|
| ABh | C8h - CFh | Demonstrate UPDATE effect | |
|
| |||
|
|
|
|
|
Valid Tach | 56H | 2010d | 5000d | Changed from 2010 RPM to 5000 RPM to show |